The 753 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software.

Work smarter. Work faster.

The 753 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis.

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
  • Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
  • Holds up to a full week of downloaded procedures and calibration results.
  • Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
  • Easy to use
  • Three year warranty
  • Bright white dual display. Read both sourced and measured parameters simultaneously.
  • Multi lingual interface
  • Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
  • Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
  • Delivered with DPC/Track Sample software.
  • Compatible with many Asset Management software packages.

Pressure Modules

Covers virtually any pressure application including gauge, differential, dual (compound), absolute, and vacuum.

  • Display pressure readings in any of 10 different pressure units you specify in the calibrator setup.
  • Rugged urethane molded cases protect the modules from rough handling and harsh conditions.
  • Features internal temperature compensation from 0º to 50º C for full accuracy performance.
  • Includes NIST-traceable calibration certificate.
  • Modules can be calibrated locally, helping to control costs.

A family of 29 optional pressure modules provides pressure calibration and measurement capabilities. Twenty-eight modules are available, with basic accuracy specs to 0.05%. Ranges start at 0 — 1 in H20 (0 — .25kPa) and go to 0 — 10,000 psi (0 — 70,000 kPa). Additional information about pressure modules is available on the Pressure Modules Home Page.

Automated Procedures

Allow you to quickly set up powerful, automated calibration procedures for linear transmitters, DP flow transmitters, and one- and two-point limit switches. Simply select the appropriate measure and/or source functions and fill out the procedure template. The 750 Series does the rest. It quickly performs the test, calculates the errors, and displays the final results, highlighting out of tolerance points.

Custom Units

Enable you to map one unit to another, such as mV to ºC or ºF. Allows you to use the Fluke 750 Series with millivolt output accessories such as the Fluke 80T-IR Temperature Probe, and to document tests using non-supported units such as parts per million or revolutions per minute.

User-entered Values

Enables technicians to record calibration results that were sourced and/or measured by other devices such as panel meters or readout-only devices.

Limit Switch Calibration

Procedures perform fast, automated calibration of one and two-point limit switches for voltage, current, temperature, and pressure.

Differential Pressure Flow Instrument Calibration

Routines use a square root function to directly calibrate DP flow instruments.

Additional Features

Multifunctional

Calibrate temperature, pressure, voltage, current, resistance, and frequency. Since it both measures and sources, you can troubleshoot and calibrate all with one rugged tool.

Powerful, yet easy to use

The easy-to-follow menu-driven display guides you through any task. Get up to speed in minutes, not days. Programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations.

Records and documents results

To support your ISO-9000 or regulatory standards the Fluke 753 captures your calibration results, eliminating the need to juggle a pen and pad in the field. The USB interface lets you transfer the results to a PC, thus saving the time of having to manually transcribe them when you return to the shop.

Truly hand-held

Small enough to fit easily into a tool bag and to use in tight spaces. Runs an entire shift on a rechargeable Li-ion battery pack.

Rugged and reliable

Count on Fluke's rugged design to deliver top accuracy and reliability in harsh environments. Overmolded urethane case stands up to rough handling in industrial environments.

Bright white display

Lets you read your results in any kind of light. Backlight has three (3) settings.

Soft keys

Provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, min/max, stepping and ramping, and review memory.

Three operating modes

Measure, Source, or simultaneous Measure/Source, - enable technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool.

Multi-lingual interface

Displays instructions in English, French, German, Spanish, and Italian.

Built-in algebraic calculator

With four functions-plus square root-stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field. Use it to set the source function to a calculated value. There's no need to carry a pencil and paper or a separate calculator.

Programmable measurement delay

Inside automated procedures permits calibrating instruments that respond slowly.

 

 

 

Measurement Accuracy

Voltage DC
 1 Year  2 Years
100.000 mV  0.02%+0.005 mV  0.03%+0.005 mV
3.00000 V  0.02%+0.00005 V  0.03%+0.00005 V
30.0000 V  0.02%+0.0005 V  0.03%+0.0005 V
300.00 V  0.05%+0.05 V  0.07%+0.05 V
Voltage AC
Range
40 to 500 Hz
 Resolution  1 Year 2 Years
3.000 V  0.001 V  0.5%+0.002 V  1.0%+0.004 V
30.00 V  0.01 V  0.5%+0.02 V  1.0%+0.04 V
300.0 V  0.1 V  0.5%+0.2 V  1.0%+0.2 V
Current DC
 1 Year  2 Years
30.000 mA  0.01% + 5 uA  0.015%+7 uA
110.00 mA  0.01% + 20 uA  0.015%+30 uA
Resistance
 1 Year  2 Years
10.000 Ω  0.05% + 50 mΩ  0.07%+70 mΩ
100.00 Ω  0.05% + 50 mΩ  0.07%+70 mΩ
1.0000 kΩ  0.05% + 500 mΩ  0.07%+0.5 Ω
10.000 kΩ  0.1% + 10 Ω  0.15%+15 Ω
Frequency
 Resolution  Accuracy (2 Years)
1.00 to 110.00 Hz  0.01 Hz  0.05 Hz
110.1 to 1100.0 Hz  0.1 Hz  0.5 Hz
1.101 to 11.000 kHz  0.001 kHz  0.005 kHz
11.01 to 50.00 kHz  0.01 kHz  0.05 kHz

Source Accuracy

Voltage DC
 1 Year  2 Years
100.000 mV  0.01%+0.005 mV  0.015%+0.005 mV
1.00000 V  0.01%+0.00005 V  0.015%+0.0005 V
15.0000 V  0.01%+0.0005 V  0.015%+0.0005 V
Current DC
 1 Year 2 Years
22.000 mA (Source)  0.01%+ 0.003 mA  0.02%+ 0.003 mA
Current Sink (Simulate)  0.02% + 0.007 mA  0.04% + 0.007 mA
Resistance
 1 Year  2 Years
10.000 Ω  0.01% + 10 mΩ  0.015% + 15 mΩ
100.00 Ω  0.01% + 20 mΩ  0.015% + 30 mΩ
1.0000 kΩ  0.02% + 0.2 Ω  0.03% + 0.3 Ω
10.000 kΩ  0.02% + 3 Ω  0.03% + 5 Ω
Frequency
 2 Years
0.1 to 10.99 Hz  0.01 Hz
0.01 to 10.99 Hz  0.01 Hz
11.00 to 109.99 Hz  0.1 Hz
110.0 to 1099.9 Hz  0.1 Hz
1.100 to 21.999 kHz  0.002 kHz
22.000 to 50.000 kHz  0.005 kHz

Technical Data

Data Log Functions
Measure functions:  Voltage, current, resistance, frequency, temperature, pressure
Reading rate:  1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length:  8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions:  Voltage, current, resistance, frequency, temperature
Rate:  4 steps/second
Trip detect:  Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage:  Selectable, 26 V
Accuracy:  10%, 18 V minimum at 22 mA
Maximum current:  25 mA, short circuit protected
Maximum input voltage:  50 V DC
Step Functions
Source Functions  Voltage, current, resistance, frequency, temperature
Manual Step  Selectable step, change with arrow buttons
Autostep  Fully programmable for function, start delay, stepvalue, time per step, repeat

Environmental Specifications

Operating Temperature
 -10 °C to +50 °C
Storage Temperature
 -20 °C to +60 °C
Dust/water resistance
 Meets IP52, IEC 529
Operating Altitude
 3000 m above mean sea level (9842 ft)

Safety Specifications

Agency Approvals
 CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993

Mechanical & General Specifications

Size
 136 x 245 x 63 mm (5.4“ x 9.6 x 2.5)
Weight
 1.2 kg (2.7 lb)
Batteries
Internal Battery Pack Li-ion:  7.2V, 4400mAh, 30 Wh
Battery Life
 >8 hours typical
Battery Replacement
 Via snap-shut door without opening calibrator; no tools required
Side port connections
 Pressure module connector
 USB Connector to interface to your PC
 Connection for optional battery charger/eliminator
Data storage capacity
 1 week of calibration procedures results
90 day specifications
 The standard specification interval for the 750 Series are 1 and 2 years.
 Typical 90 day measurement and source accuracy can be estimated by
 dividing the one year "% of reading" or "%of output" specifications by 2.
 Floor specifications, expressed as "% of full scale" or
 "counts" or "ohms" remain constant.

Temperature, Resistance Temperature Detectors

Degrees or % of reading
Type (α) Range °C Measure °C1 Source current Source °C Allowable current2
1 year 2 year 1 year 2 year
100 Ω Pt (385) -200 to 100
100 to 800
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
200 Ω Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
500 μA 0.06 °C
0.017 % + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
500 Ω Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04 % + 0.10 °C
250 μA 0.06 °C
0.017% + 0.05 °C
0.12 °C
0.034 % + 0.10 °C
0.1 mA to 1 mA
1000 Ω Pt (385) -200 to 100
100 to 630
0.07 °C
0.02 % + 0.05 °C
0.14 °C
0.04% + 0.10 °C
150 μA 0.06 C
0.017 % + 0.05 °C
0.12 C
0.034 % + 0.10 °C
0.1 mA to 1 mA
100 Ω Pt (3916) -200 to 100
100 to 630
0.07 °C
0.02 % +0.05 °C
0.14 °C
0.04 % +0.10 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
100 Ω Pt (3926) -200 to 100
100 to 630
0.08 °C
0.02 % +0.06 °C
0.16 °C
0.04 % +0.12 °C
1 mA 0.05 °C
0.0125 % + 0.04 °C
0.10 °C
0.025 % + 0.08 °C
0.1 mA to 10 mA
10 Ω Cu (427) -100 to 260 0.2 °C 0.4 °C 3 mA 0.2 °C 0.4 °C 0.1 mA to 10 mA
120 Ω Ni (672) -80 to 260 0.1 °C 0.2 °C 1 mA 0.04 °C 0.08 °C 0.1 mA to 10 mA

1For two and three-wire RTD measurements, add 0.4°C to the specifications.
2Supports pulsed transmitters and PLCs with pulse times as short as 1 ms

 

 

Model Name

Description

Fluke 753 Documenting Process Calibrator including:

  • BC7240 battery charger
  • Li-on BP7240 battery pack
  • DPCTrack 2™ Sample Software
  • Instruction manual
  • NIST-traceable calibration report and data
  • Three sets of TP220 test probes with three sets of “extended tooth alligator clips
  • Two sets AC280 hook clips
  • C799 Soft Field Case
  • USB communication cable

Accessories common to all models:

Accessory

Description

C700 Hard Carrying Case
C781 Meter Case
C799 Soft Field Case
700P00 Differential Pressure Module 1 in. H2O (0.25 kPa)
700P02 Differential Pressure Module 1 psi (6900 Pa)
700P03 Differential Pressure Module 5 psi (34 kPa)
700P04 Differential Pressure Module 15 psi (103 kPa)
FLUKE-700PCK Pressure Module Calibration Kit (Required for using 700 Series Pressure Modules with the 5520A Multi-Product Calibrator)
700PMP Pressure Pump 150 psi (10 bar)
700HTH-1 Fluke 700HTH-1 Hydraulic Test Hose
700PRV-1 Fluke 700PRV-1 Pressure Relief Valve Kit
700PTP-1 Fluke 700PTP-1 Pneumatic Test Pump
700HTP-2 Hydraulic Test Pump
700P05 Gauge Pressure Module 30 psi (207 kPa)
700P06 Gauge Pressure Module 100 psi (690 kPa)
700P07 Gauge Pressure Module 500 psi (3400 kPa)
700P08 Gauge Pressure Module 1000 psi (6900 kPa)
700P09 Gauge Pressure Module 1500 psi (10 Mpa)
700P27 Gauge Pressure Module 300 psi (2070 kPa)
700P29 Gauge Pressure Module 3000 psi (20.7 M Pa)
700P30 Gauge Pressure Module 5000 psi (34 M Pa)
700P31 Gauge Pressure Module 10000 psi (69 M Pa)
AC220 SureGrip™ Alligator Clips
AC280 SureGrip™ Hook Clips
AC285 SureGrip™ Alligator Clips
700TLK Fluke 700TLK Process Test lead kit
TL940 Mini-Hook Test Leads
TL950 Mini-Pincer Test Leads
TP74 Lantern Tip Test Probes
TP920 Test Probe Adapter Set
700P22 Differential Pressure Module Wet 1 psi (6900 Pa)
700P23 Differential Pressure Module Wet 5 psi (34 kPa)
700P24 Differential Pressure Module Wet 15 psi (103 kPa)
700PA3 Absolute Pressure Module 5 psi (34 kPa)
700PA4 Absolute Pressure Module 15 psi (103 kPa)
700PA5 Absolute Pressure Module 30 psi (207 kPa)
700PA6 Absolute Pressure Module 100 psi (690 kPa)
700TC1 Thermocouple Plug Kit 700C1
80CJ-M Type J Male Mini-Connectors
80CK-M Type K Male Mini-Connectors
80PJ-EXT Extension Wire Kit
80PK-1 Bead Probe (Type K)
80PK-22 SureGrip™ Immersion Temperature Probe
80PK-24 SureGrip™ Air Temperature Probe
80PK-25 SureGrip™ Piercing Temperature Probe
80PK-26 SureGrip™ Tapered Temperature Probe
80PK-27 SureGrip™ Industrial Surface Temperature Probe
80PK-8 Pipe Clamp Temperature Probe
80PK-9 General Purpose Probe
80PK-EXT Extension Wire Kit
700PD2 Dual Pressure Module ±1 psi (±6900 Pa)
700PD3 Dual Pressure Module ±5 psi (±34 kPa)
700PD4 Dual Pressure Module ±15 psi (±103 kPa)
700PD5 Dual Pressure Module –15 to 30 psi (–100 to 207 kPa)
700PD6 Dual Pressure Module –15 to 100 psi (–100 to 690 kPa)
700PD7 Dual Pressure Module –15 to 200 psi (–100 to 1380 kPa)
700PV3 Vacuum Pressure Module –5 psi (–34 kPa)
700PV4 Vacuum Pressure Module –15 psi (–103 kPa)
BC7240 Battery charger/Eliminator for 75x
BP7240 Li-Ion Battery Pack for 75x
700-IV Current Shunt
700SW Fluke 700 SW DPC/TRACK Software
750SW Fluke 750 SW DPC/TRACK2 Software

 

Request a quote - Shop

  • Any additional requirements? Please let us know.
  • This field is for validation purposes and should be left unchanged.

Call Now Button