2182A Nanovoltmeter

The two-channel Model 2182A Nanovoltmeter is optimized for making stable, low noise voltage measurements and for characterizing low resistance materials

 

In our effort to bring our customers the highest level of precision measurement capabilities, Fluke Calibration is proud to offer these precision metrology grade products from Keithley Instruments. Renowned as a leader in low-level precision electrical measurements, these selected Keithley products present an opportunity to help you further reduce uncertainties in your lab.

The two-channel Model 2182A Nanovoltmeter is optimized for making stable, low noise voltage measurements and for characterizing low resistance materials and devices reliably and repeatably. It provides higher measurement speed and significantly better noise performance than alternative low voltage measurement solutions.

  • 7 1/2 digit resolution provides 1 nV sensitivity on 10 mV setting
  • High accuracy: +/- (2 ppm rdg + 1 ppm rdg)
  • 3x lower noise than the Agilent 34420A at 1 PLC
  • Make low noise measurements at high speeds, typically just 15 nV p-p noise at 1s response time, 40-50 nV p-p noise at 60 ms
  • Delta mode coordinates measurements with a reversing current source at up to 24 Hz with 30 nV p-p noise (typical) for one reading. Averages multiple readings for greater noise reduction
  • Synchronization to line provides 110 dB NMRR and minimizes the effect of ac common-mode currents
  • Dual channels support measuring voltage, temperature, or the ratio of an unknown resistance to a reference resistor
  • Built-in thermocouple linearization and cold junction compensation

 

 

 

Summary specifications

Display VFD
Digit Resolution 7.5 digits (Channel 1,2)
Volts DC Ranges: 10 mV to 100 V
Min. resolution: 1 nV
Best accuracy: 18 PPM of reading +2PPM of range (90 day)
Input resistance: >10G Ohms
Noise performance at 25 second response time 10 mV range 6 nV
100 V Range 75 mVolts
CMRR 140 dB
Analog Output Max. output
Accuracy
2 M Ohms to 200 T Ohms
Thermocouple Types J, K, N, T, E, R, S, B
Resolution 0.001 degree C  (R, S, B, 0.1 degree C)
Accuracy +/-0.2 degrees C
Calibration Documentation Traceable calibration report included (no data); Z540.1 or 17025 accredited report optional
Remote interface GPIB (IEEE-488.2) and RS-232C
SCPI (Standard Commands for Programmable Instruments)
Math Functions REL, Min/Max/Average, Std Dev./Peak-to-Peak, Limit Test, %, mX+b

 

 

Model Name

Description

2182A Nanovoltmeter

Accessories common to all models:

Accessory

Description

2107-4 Low Thermal Input Cables
2107-30 Low-Thermal Input Cable
2187-4 Low Thermal Test Lead Kit
2188 Low Thermal Calibration Shorting Plug
4288-1 Single, Fixed Rack Mount Kit
4288-2 Dual, Fixed Rack Mount Kit

 

      Product manuals

 

      Data sheets

 

      Specifications

 

      Instruction sheets

 

Request a quote - Shop

  • Any additional requirements? Please let us know.
  • This field is for validation purposes and should be left unchanged.