Omega HH21 calibration and repair

Home → Calibration Service → Electrical calibration → Omega → Omega HH21 calibration and repair

Have your Omega equipment calibrated in the  ISO/IEC 17025 accredited lab!

Minerva is specialized in repair and calibration services of Omega instruments. These Omega instruments are calibrated in a ISO/IEC 17025 accredited calibration lab.  

The calibration is performed by calibration technicians. We have more then 30 years of experience in calibrating Omega instruments. In short, your Omega instrument is taken good care off! We focus on a fast lead time and extremely high standard of our service.

Omega HH-21 Microprocessor-based handheld thermometer

The HH-20A series microprocessor-based handheld thermometers offer wide-ranging temperature readings and feature state-of-the-art innovations. The easy-to-read custom 5-digit LCD readout with trend display and self-diagnostics are all standard. The case is drop/splash and dust-proof, and has a built-in tilt stand/handle for bench use or hands-free field measurements.

The HH-21A is a single input unit that accepts J, K and T thermocouple types. From the front panel, the user can select the thermocouple type, display units (°C or °F), and display resolution (0.1° or 1°). The HH-21A also has a display hold function. As with all HH-20A series units, the HH-21A features exceptionally high accuracy, 0.1% of reading plus 1°F.

The HH-22A and HH-23A accept dual inputs. The HH-22A accepts either J or K thermocouples, while the HH-23A works with J, K or T types. Both models can display T1 (input 1), T2 (input 2), T1-T2 (difference), or scan between T1, T2 and T1-T2. Standard features for both the HH-22A and HH-23A include display hold, min and max storage, and trend indication. The min and max functions record minimum and maximum values for T1, T2 and T1-T2. Trend indication shows if the displayed input is increasing, decreasing or stable.

When you turn on an HH-20A, it remembers what you were doing; the thermocouple type, resolution, and temperature units are stored in non-volatile memory so you don’t have to reprogram every time you start up

SPECIFICATIONS
Display: 5-digit LCD; custom indicators for thermocouple type°C/°F units, hold and low battery; HH-22A and HH-23A have additional indicators for input (T1, T2, T1-T2, scan), up/down trend arrows and min/max data storage
Keypad: Momentary switches with tactile feedback; on/off, thermocouple type, units, resolution, hold; HH-22A and HH-23A have additional keys for record min/max, view min/max, stop/clear record input type (T1, T2, T1-T2, scan)
Configuration Retention: Selected readout, input type, units and resolution retained on power-off
Diagnostics: Low battery, open thermocouple, invalid keypad entry, out of range, internal hardware fault
Accuracy: 0.1% rdg + 0.5°C (1°F)
Repeatability: 0.2°C for 1 week at constant temperature
Resolution: 0.1° throughout entire range
Temperature Coefficient: (0.02% rdg + 0.1°C) below 64°F (18°C) and over 82°F (28°C); included in accuracy, between 18 and 28°C (64 and 82°F)
Ambient Temperature: 0 to 50°C (32 to 122°F), 0 to 90% RH
Reading Rate: 1 per second
Max Common Mode Voltage: 42 V peak to earth ground
Power: 9 Vdc battery, alkaline (included)
Battery Life: 100 h, typical, alkaline battery
Dimensions: 178 H x 74 W x 28 mm D (7.0 x 2.9 x 1.1″)
Weight: 284 g (10 oz)
Accessories Included: 9 Vdc alkaline battery, beaded wire Type K probe (for each input), integral tilt stand/ handle, wrist strap, rubber holster and operator’s manual

 

aq4320d
Call Now Button