Tektronix TDS3000-Series calibration and repair

Home → Calibration Service → Electrical calibration → Tektronix → Tektronix TDS3000-Series calibration and repair

Have your Tektronix equipment calibrated in the  ISO/IEC 17025 accredited lab!

Minerva is specialized in repair and calibration services of Tektronix instruments. These Tektronix instruments are calibrated in a ISO/IEC 17025 accredited calibration lab.  

The calibration is performed by calibration technicians. We have more then 30 years of experience in calibrating instruments. In short, your Tektronix instrument is taken good care off! We focus on a fast lead time and extremely high standard of our service.

Tektronix TDS3000-Series Digital Phosphor Oscilloscope

Features & Benefits

  • 500 MHz, 300 MHz, and 100 MHz Bandwidths
  • Sample Rates up to 5 GS/s
  • 2 or 4 Channels
  • Full VGA Color LCD on all Models
  • Built-in Floppy Disk Drive For Easy Storage and Documentation
  • 21 Automatic Measurements
  • Centronics Port Standard on all Models for Quick, Convenient Hardcopies
  • 9-bit Vertical Resolution
  • Multi-Language User Interface
  • QuickMenu User Interface Mode for Quick, Easy Operation
  • Optional Modules for RS-232, GPIB, LAN or VGA Communication Ports
  • Advanced Triggers, such as, Glitch, Width, and Logic Standard on 4 Channel Models
  • Telecommunications Mask Testing (TMT)
  • Fast Fourier Transform (FFT) for Frequency and Harmonic Analysis Standard on 4 Channel Models
  • Extended Video Application Module
  • Support for Active Probes, Differential Probes, and Current Probes that Provide Automatic Scaling and Units
TDS3000 Series Electrical Characteristics

 

TDS3012

TDS3032

TDS3052

TDS3014

TDS3034

TDS3054

Bandwidth

100 MHz

300 MHz

500 MHz

100 MHz

300 MHz

500 MHz

Channels

2

2

2

4

4

4

Sample Rate on Each Channel

1.25 GS/s

2.5 GS/s

5 GS/s

1.25 GS/s

2.5 GS/s

5 GS/s

Maximum Record Length

10K points on all models

Vertical Resolution

9–bits on all models

Vertical Sensitivity (/div)

1 mV-10 V on all models

Vertical Accuracy

±2% on all models*1

Max Input Voltage (1 megohm)

150V RMS CAT I on all models

Position Range

±5 div on all models

BW Limit

20 MHz

20, 150 MHz

20, 150 MHz

20 MHz

20, 150 MHz

20, 150 MHz

Input Coupling

AC, DC, GND on all models

Input Impedance Selections

1 megaohm in parallel with 13 pF, or 50 ohm

Time Base:

 

Range (/div)

4 ns – 10 s/div

2 ns – 10 s/div

1 ns – 10 s/div

4 ns – 10 s/div

2 ns – 10 s/div

1 ns – 10 s/div

Accuracy

200 ppm

200 ppm

200 ppm

200 ppm

200 ppm

200 ppm

Display Monitor

Color LCD

*1 Derated at 0.07%/°C for temperatures above +28°C and below +18°C.

 

 