Fluke 5700A/5720A Multifunction Calibrators

The 5700A/5720A have been discontinued. For a more up-to-date, improved solution, see the 5730A Multifunction Calibrator.

 

Technical Specifications

Voltage DC
Ranges:  0 to ±1100V
5700A Best 1 Year Specification:  ±7.0 ppm of setting
5720A Best 1 Year Specification:  ±3.5 ppm of setting
Voltage AC
Ranges:  220 mV to 1100V
   10 Hz to 1 MHz
5700A Best 1 Year Specification:  ±75.0 ppm of setting
5720A Best 1 Year Specification:  ±45.0 ppm of setting
Resistance
Ranges:  0 to 100 MΩ, 18 values in x1 and x1.9
5700A Best 1 Year Specification:  ±12.0 ppm
5720A Best 1 Year Specification:  ±8.5 ppm
Current DC
Ranges:  0 to ±2.2A (11A with 5725A)
5700A Best 1 Year Specification:  ±50 ppm of setting
5720A Best 1 Year Specification:  ±35 ppm of setting
Current AC
Ranges:  9 mA to 2.2A (11A with 5725A) 10 Hz to 10 kHz
5700A Best 1 Year Specification:  ±140 ppm of setting
5720A Best 1 Year Specification:  ±120 ppm of setting
Wideband AC Voltage Option
Ranges:  300 mV to 3.5V
   10 Hz to 30 MHz
5700A Best 1 Year Specification:  ±0.4% of setting
5720A Best 1 Year Specification:  ±0.4% of setting

General Specifications

Warm up Time
   2x the time since last warmed up, to a maximum of 30 minutes
System Installation
   Rear output configuration and rack-mount kit available
Interfaces
   IEEE-488, RS-232, 5725A, 5205A or 5215A, 5220A, phase lock in (BNC), phase reference out (BNC)
Temperature Performance
Operating:  0°C to 50°C
Calibration:  15°C to 35°C
Storage:  -40°C to 75°C
Relative Humidity
Operating:  < 80% to 30°C, < 70% to 40°C, < 40% to 50°C
Storage:  < 95%, non-condensing. A power-on stabilization period of four days may be required after extended storage at high temperature and humidity.
Safety
   Designed to comply with UL311; IEC 348-1978; IEC 66E (CO)4; CSA 556B
Guard isolation
   20 volts
EMI/RFI
   Designed to comply with FCC Rules Part 15, Subpart J, Class B; VDE 0871, Class B
Line Power
   47 to 63 Hz; + 10% allowed about selectable nominal line voltage: 100V, 110V, 115V, 120V, 200V, 220V, 230V, 240V
   --------------
Maximum power:  5700A/5720A: 300 VA;5725A, 750 VA
Calibration Documentation 17025 accredited report of calibration included
Size
5700A/5720A:  Height 17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet; width 43.2 cm (17 in), standard rack width; depth 63.0 cm (24.8 in) overall; 57.8 cm (22.7 in), rack depth
5725A:  Height 13.3 cm (5.25 in); width and depth same as 5700A/5720A
   Both units project 5.2 cm, (2 in) from rack front
Weight
5700A/5720A:  27 kg (62 lbs.)
5725A:  32 kg (70 lbs.)
   

 

 

Model Name

Description

5720A Multifunction Calibrator
5700A Series II Multifunction Calibrator

 

Accessories common to all models:

   

Accessory

Description

5440A-7002 Low Thermal Copper EMF Plug-In Cables, Banana Connectors
5440A-7003 Low Thermal Copper EMF Plug-In Cables, Spade Connectors
57XX/CASE Transit Case for 57XXA Series
5700A-03 Wideband AC Voltage (compatible with both the 5700A and the 5720A
5725A Amplifier
Y5735 Rack Mount Kit for 5725A
Y5737 5790A and 5700A/5720A Rack Mount Kit. Includes 24 in. slides that allow for side ventilation

 

Request a quote - Shop

  • Any additional requirements? Please let us know.
  • This field is for validation purposes and should be left unchanged.