P3100 Hydraulic Deadweight Testers

The P3100 Models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa.

 

  • Pressure ranges to 20,000 psi (1400 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC

The P3100 Models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa. These robust instruments are highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.

The P3100 Series is the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation these deadweight testers can be used to calibrate virtually any pressure sensing device, including transducers, transmitters, gauges or pressure switches.
Each instrument is supplied with a detachable lid which makes it neat, compact and easily portable. The weight masses are stored in a high-quality case with a self locking mechanism to protect them during transit.
All units are provided with a traceable certificate of accuracy, weight mass details, 1/8 inch, 1/4 inch, 3/8 inch and 1/2 inch NPT or BSP female adaptors, operating fluid (where applicable) and spare seals.
The piston/cylinder assemblies are manufactured to the very highest standards with certified accuracies traceable to international standards laboratories such as the National Institute of Standards and Technology (NIST).

 

Operating principle

Deadweight testers are the high performance pressure standards for pressure measurement. Utilizing the well proven piston-gauge system consisting of a vertically mounted, precision lapped piston and cylinder assembly, accurately calibrated weight masses (Force) are loaded on the piston (Area), which rises freely within its cylinder. These weights balance the upward force created by the pressure within the system. The pressure is measured when placed on a correctly spinning and floating piston. The total pressure measured is the summation of the weights plus the piston weight carrier assembly.

Instrument base

There are three basic variations in the hydraulic offering; single low pressure, single high pressure and dual piston models. Pressure is generated and controlled by means of a high quality screw press located on the front of the tester. A built-in hand pump is included as standard for all hydraulic models to prime the system and accommodate large volume requirements.
 

Piston/cylinder assemblies

The piston/cylinder assembly is the heart of each deadweight tester. They are manufactured from materials that provide stability, durability, and low thermal coefficients and distortion. Our experience and knowledge of piston/cylinder production and calibration ensure the precision and performance required for today’s demanding calibration requirements.
 

Weight masses

Standard weight masses are series 3 nonmagnetic austenitic stainless steel. Each mass is marked with the serial number of the instrument and the nominal pressure value relative to the high or low-pressure piston, when applicable. Optional fractional weights are stainless steel and/or solution heat treated aluminum.
 

Gravity correction

Gravity varies significantly with geographical location and this variation has a direct effect on the force of the weights and the accuracy of the deadweight tester. Each instrument can be calibrated to local gravity at no extra cost. If unspecified, instruments will be calibrated to Standard Gravity at 980.665 cm/s2.

 

 

Pressure Ranges

Oil operated Ranges to 20,000 psi (1400 bar)

Accuracy

Accuracy* ±0.015% of reading (±0.008% optional)
*Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.

Materials of Construction

Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminum
Weight density 2.7 g/cm³
Piston material Tungsten carbide with nickel binder
Density- 15.0 g/cm³
Cylinder material Hardened martensitic steel
Tungsten carbide (water above 500 psi, 35 bar)
Thermal coefficients of expansion Oil piston/cylinder 16.5 ppm/°C
Water (above 500 psi, 35 bar) 11 ppm/°C

General

Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 36 lbs (16 kg)
Instrument size 17.5 W x 12 D x 8.5 H
Mass set weight (typical) 80 lbs (36 kg)
Reservoir volume 150 cc
Screw press displacement 5.5 cc
Pump displacement 4.7 cc per stroke
O-ring seal materials Buna N as standard, Viton and EPDM available

Weight Increments

Minimum Standard Weight Increments Up to 500 psi (35 bar): 1 psi (0.1 bar)
500 to 5000 psi (35 to 350 bar): 10 psi (1 bar)
5000 to 20,000 psi (350 to 1400 bar): 20 psi (2 bar)
Model P3112: 1 psi (0.1 bar)
Optional Fractional Weights Up to 500 psi (35 bar): 0.1 psi (0.01 bar)
500 to 5000 psi (35 to 350 bar): 1 psi (0.1 bar)
5000 to 20,000 psi (350 to 1400 bar): 2 psi (0.2 bar)

Operating Fluid

Mineral oil Shell spindle oil 22, our reference 55-655, viscosity 40 cs@ 20°C

Options

PressCal Software Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments.

 

 

Model Name

Description

P3111-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 1 to 35 bar
P3111-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 1 to 35 kgf/cm²
P3111-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 10 to 500 psi
P3111-KPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 100 to 3,500 kPa
P3111-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 0.1 to 3.5 MPa
P3112-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 4 to 140 bar
P3112-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 4 to 140 kgf/cm²
P3112-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 40 to 2,000 psi
P3112-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 0.4 to 14 MPa
P3113-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 10 to 350 bar
P3113-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 10 to 350 kgf/cm²
P3113-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 100 to 5,000 psi
P3113-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 1 to 35 MPa
P3114-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 700 bar
P3114-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 700 kgf/cm²
P3114-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 200 to 10,000 psi
P3114-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 2 to 70 MPa
P3115-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 1,100 bar
P3115-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 1,100 kgf/cm²
P3115-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 200 to 16,000 psi
P3115-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 2 to 110 MPa
P3116-BAR Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 1,400 bar
P3116-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 20 to 1,400 kgf/cm²
P3116-PSI Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 200 to 20,000 psi
P3116-MPA Hydraulic Deadweight Tester
Oil Operated - Single PCU
Pressure Range 2 to 140 MPa
P3123-BAR Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 350 bar
P3123-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 350 kgf/cm²
P3123-PSI Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 10 to 5,000 psi
P3123-MPA Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 0.1 to 35 MPa
P3124-BAR Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 700 bar
P3124-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 700 kgf/cm²
P3124-PSI Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 10 to 10,000 psi
P3124-MPA Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 0.1 to 70 MPa
P3125-BAR Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 1,100 bar
P3125-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 1,100 kgf/cm²
P3125-PSI Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 10 to 16,000 psi
P3125-KGCM2 Hydraulic Deadweight Tester
Oil Operated - Dual PCU
Pressure Range 1 to 1,100 kgf/cm²

 

Accessories common to all models:

   

Accessory

Description

5540 Metric and 5541 BSP Adapter Sets P5540 Metric
M14 x 1.5, M20 x 1.5, 1/8 and 1/4 BSPP5541 BSP
1/8, 1/4, 3/8 and 1/2 BSPP5542 NPT
1/8, 1/4, 3/8 and 1/2 NPT
P5521 and P5522 Liquid-to-Liquid Separators These liquid-to-liquid separators connect directly to the test port of a hydraulic deadweight tester or comparison test pump. A flexible diaphragm separates the fluids, protecting the calibrator from contamination, and allows calibration of the device in its specific working fluid.
P5523 Liquid-to-Gas Media Separator

Pressure range 0 to 3,000 psi (210 bar)

For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to-gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.

* Note---since fluid mist may be transferred during operation we do not recommend this device for oxygen safe instruments using an oil operated deadweight tester.

P5543 Angle Adapter To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges at 90º. The maximum working pressure of this unit is 10,000 psi (700 bar).
P5544 Two Gauge Stand This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar).
P5551 Pointer Remover/Punch This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge.

 

Request a quote - Shop

  • Any additional requirements? Please let us know.
  • This field is for validation purposes and should be left unchanged.

Call Now Button